Experto solar fuera de la red - Solarker

Inicio / todos / Solar Heat Pump /

-25℃ EVI Hybrid ACDC Solar Air Source Heat Pump Air Conditioner R32

-25℃ EVI Hybrid ACDC Solar Air Source Heat Pump Air Conditioner R32

-25℃ EVI Hybrid ACDC Solar Air Source Heat Pump Air Conditioner R32
-25℃ EVI Hybrid ACDC Solar Air Source Heat Pump Air Conditioner R32-25℃ EVI Hybrid ACDC Solar Air Source Heat Pump Air Conditioner R32-25℃ EVI Hybrid ACDC Solar Air Source Heat Pump Air Conditioner R32-25℃ EVI Hybrid ACDC Solar Air Source Heat Pump Air Conditioner R32-25℃ EVI Hybrid ACDC Solar Air Source Heat Pump Air Conditioner R32
CategoríaSolar Heat Pump
MarcaSolarker Hybrid ACDC Solar
ModeloSKWLA1-ACDC-18KR2
Grid Power AC208V-240V/50-60HZ
Solar Panel DC Power80-380V DC
Rated Cooling Capacity(35℃)17000(4200-18700)
Rated Cooling Power input(35℃)1220(210-1580)
Heating Capacity(7℃)5200(1200-5600)
Heating Power Input(7℃)1200(220-1720)
Heating Capacity(-10℃)5000(1200-5500)
Power input(-10℃)1950(220-2430)
Heating Capacity(-22℃)4400(1200-4600)
Power input(-22℃)2100(220-2400)
SEER(EN14825:2018)7.51 A++
SCOP(Average)4.21 A+
descargar
Tiempo de Actualización2024/11/13
Información Detallada
Solarker -30℃ EVI Hybrid ACDC Heat Pump Air Conditioner R32 for Europe
SKWLA1-ACDC-18KR2    SKWLA1-ACDC-24KR2
Solarker -30℃ EVI Heat Pump
When the outdoor temperature is 0 to -4°C, the heating capacity of the normal air conditioner or heat pump is about 60% of the nominal heating capacity (design heating capacity), and the actual heating capacity is about 40% of the nominal heating capacity when the temperature is -5°C to -6°C, In an environment below -7°C, the air conditioner has almost no heating due to the frequent defrosting of the outdoor unit of the air conditioner.

If you live in a cold area such as Eastern Europe, Northern Europe, Russia, Canada, etc., the temperature in winter is often lower than -5 ℃, then choosing Solarker -30 ℃ EVI heating heat pump will be the most economical, the lowest cost, The best thermal solution. Combined with the Hybrid ACDC solar panel technology, you can get energy-efficient heating even during the day without using any grid power.

The Solarker -30℃ EVI Hybrid ACDC  heat pump air conditioner energy efficiency reach A++ in summer cooling, reach A+ in winter heating, which is the top level split type DC inverter appliances. Compared with the central water heat pump, it can be easily installed and also get rapid heating for the houses.
Low temperature air source heat pump solarker
-30℃ EVI Heating Technology & DC Inverter Vapor Injection Compressor
Solarker -30℃ EVI Technology
Evaporator flash tank separate gas and liquid refrigerant, gaseous refrigerant enters the suction port of compressor and reaches the intermediate chamber of the compressor. 

It increases compressor inside temperature and then increase compressor outlet exhaust temperature, so compressor enthalpy increase and efficiency improve.


Solarker EVI air source heat pump -25C
DC Inverter +  EEV Technology
The full DC inverter technology control the speed of compressor from 15HZ to 85HZ, adjusts the input power from minimum 200W to maximum 2500W according to the ambient temperature needs to achieve the first energy saving 20-30%.

EEV technology achieves precisely control of R32 refrigerant flow, achieving the second energy saving effect and precisely control the room temperature.
Solarker DC inverter air conditioner
DC Inverter Vapor Injection Compressor
1/Under SEER60, COP reach 3.95
2/Heating Capacity increase 20-50% at -15°C
3/Two-stage throttling and compressing
4/Twin Rotary, stable and powerful
5/Lowest working ambient temp: -30°C
6/Maximize Air outlet temp 55°C at -20°C
solar air conditioner compressor
Integrated Solar Mppt Controller
The solar PV panel can easily connected to the outdoor unit with MC4 connector.
The unit with both high EER cooling and high COP heating.


Solarker EVI heat pump
WiFi and Bluetooth Remote Control
Through WiFi or Bluetooth you can connect your house air conditioner with your Android or Iphone mobile phone, and control anywhere of the devices. Owner can share devices to your family or workers and you can control multy split floor console separately or in group.
Solarker solar heat pump WiFi
APP Power Meter Data
View real-time power generation data of solar panels and grid power consumption, daily, monthly, and annual historical power data through the APP, clearly to know how much energy saving everywhere and anytime

Solarker solar air source heat pump
Parameter
Solarker Hybrid ACDC -25°C Solar Air Source Heat Pump Air Conditioner
Unit SKWLA1-ACDC-18KR2 SKWLA1-ACDC-24KR2
Grid Power AC Ph-V-Hz 208V-240V/50-60HZ 208V-240V/50-60HZ
Solar Power DC VMP V 80-380V 80-380V
Solar Power DC ISC A
Rated Cooling Capacity(35) BTU 17000(4200-18700) 24000(4200-26000)
Power input(35) W 1220(210-1580) 2080(270-2560)
 EER   (35) (W/W)/ (BTU/W) 4.10/13.95 3.36/11.54
Heating Capacity(7) W 5200(1200-5600) 7200(2000-8200)
Heating Power input(7) W 1200(220-1720) 1800(280-2620)
COP (7) (W/W)/ (BTU/W) 4.33/14.78 4.00/13.71
Heating Capacity(-10) W 5000(1200-5500) 7000(1500-7400)
Heating Power input(-10) W 1950(220-2430) 2800(270-2430)
COP (-10) (W/W)/ (BTU/W) 2.56/8.75 2.50/8.57
Heating Capacity(-22) W 4400(1200-4600) 6400(1500-6500)
Heating Power input(-22) W 2100(220-2400) 3350(220-3450)
COP (-22) (W/W)/ (BTU/W) 2.09/7.15 1.91/6.50
SEER(EN14825:2018) W/W    7.51  A++ 6.52  A++
SCOP(Average) W/W    4.21  A+ 4.36 A+
SCOP(Colder) W/W    3.41 A 3.45 A
Compressor Type  / Twin ROTARY EVI Inverter Twin ROTARY EVI Inverter
Brand  / GMCC GMCC
Indoor fan motor / ZWR45-C51 KAIBANG ZWR45-C51 KAIBANG
Indoor unit Dimension(W×H×D) mm 1080×330×237 1080×330×237
Indoor unit Packing   (W×H×D) mm 1140×300×382 1140×300×382
Indoor unit Net/Gross weight   Kg 15.0/17.5 15.0/17.5
Outdoor fan motor / ZWB278L56A WOLONG ZWB278L56A WOLONG
Outdoor unit Dimension(W×H×D) mm 900×700×337 951×873×386
Outdoor unit Packing  (W×H×D) mm 1006×755×418 1085×1000×430
Outdoor unit Net/Gross weight   Kg 44.5/49.0 60/71
Refrigerant type g R32 R32
Max pressure  Discharge/Suction MPa 4.3/1.5 4.3/1.5
Pipe Size Gas/Liquid inch  1/2   1/4   1/2   1/4 
Max. refrigerant pipe length   m 15 20
Max. difference in level     m 8 10
EEV / SANHUA SANHUA
Solar Features
Download
Solarker Installation Manual
ACDC Solar Air Conditioner Solarker
Evaluacion
  • Cargando...
Productos Relacionados
    Póngase en contacto con nosotros en cualquier momento para obtener una muestra o probar el pedido de cualquier producto solar
    *Email
    Teléfono
    *Título
    *Contenido
    Subir
    • Solo admite .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, máximo 20M

    Experto en aplicaciones solares 100% CC fuera de la red